Capacity L 500 800 1000 1500
Capacity of water tank DHW / Buffer tank L1/l2 22/478 25/775 25/975 40/1460
Height without insulation / with insulation H, Hi, mm 1700/1750 1840/1890 2040/2090 2170/2220
Min. vertical clearance mm 1720 1865 2074 2262
Diameter without insulation / with insulation D, mm Ø 650/850 Ø 790/990 Ø 790/990 Ø 1000/1200
Heat exchange surface E, m2 5.5 6.11 6.11 9.9
Heat exchange surface – Lower/Upper coil S1/S2 S1, S2m2 1.7/1.0 2.9/1.8 3.0/2.0 3.4/2.4
Capacity Lower/Upper coil S1/S2 L 10.5/6.2 17.9/11.1 18.5/12.3 21.0/14.8
Heating power of the lower / upper coil
(from an additional heat source)
kW 37/19 72/39 75/42 91/55
Lower / Upper Productivity 80оС/60оС (from an additional heat source) L/h 1590/816 3095/1677 3224/1806 3912/2365
Recommended Absorber Heat exchange surface of Solar Collectors m2 8.00 12.00 14.00 22.00
Operating pressure/Max. coil temperature bar/0C 16/110 16/110 16/110 16/110
Operating pressure / Max. buffer temperature bar/0C 3/95 3/95 3/95 3/95
Operating pressure / Max. DHW tube temperature. bar/0C 6/95 6/95 6/95 6/95
Weight without insulation / with insulation kg, kg i 164/176 213/229 230/248 352/375
Recommended boiler size, connected to buffer tank kW 44 75 75 114
Continuous outflow 10/45°C, buffer tank is charged to 65°C Е, 10/45°C,
L/h
1080 1840 1840 2800
Continuous outflow 10/38°C, buffer tank is charged to 65°C. Е, 10/38°C,
L/h
1350 2300 2300 3500
Single discharge capacity up to 38°C (when the buffer is charged to 65°C) Е,38°C, L 375 580 790 1150
ΔT -temperature difference between buffer tank and DHW at flow rate  30/40/50 liters/minute.. Е, ΔT 6.8.12 3.5/5/8 3.5/5/8 2/3/5
Water stratification unit Ø, mm Ø140 Ø140 Ø140 Ø140
Boiler heat carrier outlet С1, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170 Rp11/2”/235
Boiler heat carrier outlet С2, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170 Rp11/2”/235
Boiler heat carrier outlet C3, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170 Rp11/2”/235
Outlet heat carrier/lower coil S1 S1o, mm Rp1”/280 Rp1”/310 Rp1”/310 Rp1”/375
Boiler heat carrier С4, mm Rp1”/430 Rp1”/470 Rp1”/500 Rp1”/690
Boiler heat carrier С5, mm Rp11/2”/1030 Rp11/2”/1050 Rp11/2”/1210 Rp11/2”/1405
Outlet heat carrier/upper coil S2 S2o, mm Rp11/2”/1030 Rp11/2”/1050 Rp11/2”/1210 Rp11/2”/1405
Heat carrier inlet С7, mm Rp11/2”/1450 Rp11/2”/1550 Rp11/2”/1740 Rp11/2”/1820
Heat carrier inlet C8, mm Rp11/2”/1450 Rp11/2”/1550 Rp11/2”/1740 Rp11/2”/1820
Inlet heat carrier/lower coil S1 S1i, mm Rp1”/775 Rp1”/845 Rp1”/930 Rp1”/1045
Inlet heat carrier/upper coil S2 S2i, mm Rp11/2”/1360 Rp11/2”/1410 Rp11/2”/1570 Rp11/2”/1720
Sensor sleeve А1, mm Rp1/2”/540 Rp1/2”/590 Rp1/2”/620 Rp1/2”/800
Sensor sleeve А2, mm Rp1/2”/650 Rp1/2”/710 Rp1/2”/770 Rp1/2”/920
Sensor sleeve А3, mm Rp1/2”/1140 Rp1/2”/1160 Rp1/2”/1320 Rp1/2”/1520
Sensor sleeve А4, mm Rp1/2”/1420 Rp1/2”/1520 Rp1/2”/1700 Rp1/2”/1790
Boiler heat carrier / Electric heating element В, mm Rp11/2”/900 Rp11/2”/930 Rp11/2”/1050 Rp11/2”/1280
Air Vent F, mm Rp11/2”/1700 Rp11/2”/1840 Rp11/2”/2040 Rp11/2”/2170
Inlet/outlet DHW coil (tube) Еi/Eo, mm
Rp1”
250/1480 270/1590 310/1760 345/1850
Thermometer T оption